Sealey SM22/C User Manual

Browse online or download User Manual for Tools Sealey SM22/C. Sealey SM22/C User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 3
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY
CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
 WARNING! Ensure Health & Safety, local authority, general workshop practice regulations are adhered to when using equipment.
 WARNING! Installation site must be equipped with suitable fire extinguishers (water must not be used) and escape routes.
 WARNING! Disconnect the air supply from the tank before changing accessories, servicing or performing any maintenance.
Maintain the tank in good condition (use an authorised service agent).
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
Locate the tank in a suitable work area. Ensure the tank stands on a firm level surface. Keep area clean and tidy and free from unrelated
materials. Ensure the area is well ventilated and has adequate lighting.
WARNING! Ensure specified air pressure is maintained and not exceeded.
Keep air hose away from heat, oil and sharp edges. Check air hose for wear before each use, and ensure that all connections are secure.
WARNING! This tank is recommended for use only with degreasing solvents suitable for air operated tanks. Ensure you follow
makers instructions for solvent use.
When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from
closing fully if and when the fusible link activates.
In case of fire in tank, do not attempt to move unit or remove parts from tank. The lid is fusible and will automatically close extinguishing fire.
Ensure solvent flash point is above 140°F. We recommend you use Sealey solvent, contact your local dealer for details.
Keep the tank clean. Remove and clean the suction filter regularly for best performance.
 DO NOT modify or jam the parts washer lid open, as this will make the fusible fire link inoperative which is dangerous practice and will
invalidate the warranty and your insurance.
When cleaning parts ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from
closing fully if and when the fusible link activates.
WARNING! DO NOT SMOKE and keep sources of ignition, such as heaters, lamps, etc. away from the unit, together with
flammable or combustible materials, as there is an explosion risk.
WARNING! Wear approved safety eye protection, mask and gloves. If solvent gets on skin or in eyes wash thoroughly with water
and take any other action as required by the solvent instructions.
Remove ill fitting clothing, ties, watches, rings and other loose jewellery, contain long hair, and wear appropriate protective clothing.
Maintain correct balance and footing. Ensure the floor is not slippery and wear non-slip shoes.
Keep non-essential persons away from the work area.
Avoid accidental starting of the washer by ensuring the unit is disconnected from the air supply when not in use.
DO NOT use the tank for any purpose other than for which it is designed.
DO NOT operate the tank if any parts are missing or damaged as this may cause failure or possible personal injury.
DO NOT over-fill the tank.
 DO NOT use air line to blow dry components in tank. Only use air gun supplied. DO NOT direct air gun at yourself or others.
 DO NOT leave the parts washer operating unattended.
When cleaning is complete, ensure that all controls are in the ‘off’ position and that the air supply is disconnected.
 WARNING! It is operator’s responsibility to ensure that there is no uncontrolled discharge of any fluids used with this unit and that
appropriate arrangements have been made for correct disposal of waste in accordance with government/local authority regulations.
2. INTRODUCTION & SPECIFICATION
3. ASSEMBLY
As you unpack the product, check contents. Should there be any damaged or missing parts contact your supplier immediately.
3.1. Remove all parts from the carton and from inside the tank.
3.2. Lay clean cardboard on the floor to protect the tank paint work and carefully turn the tank upside down whilst holding the lid closed.
3.3. Assemble legs to the brackets on the bottom of the tank with screws and hex nuts, (hand tight only).
3.4. Set the lower shelf among the four legs and fix with screws and hex nuts. Level the shelf and tighten screws.
3.5. Now tighten the leg screws and carefully turn assembled unit up correct way onto it’s legs whilst holding the lid closed.
3.6. Position unit according to safety instructions in Section 1.
3.7. Open lid and place the pump control box through the rectangular hole on the side of tub.
3.8. Screw the 90° connector into the welded bolt on pump housing, then fit the flexible tube to the 90° connector.
3.9. Place the work shelf onto the welded supports inside the tank.
3.10. Check that the tank drain plug is correctly inserted and tightened.
3.11. Place the parts basket on work shelf. Check your installation to ensure the unit is ready for connecting to the air supply.
INSTRUCTIONS FOR:
WORKSHOP AIR POWERED CLEANING TANK
MODEL No:
SM22/C
Specification
Operation Pressure ........................90psi
Air Consumption........................... 6cfm
Air Inlet ............................... 1/4”BSP
Tank Height/Width/Length ..........265/500/730mm
Overall Height...........................890mm
Air operated Industrial cleaning tank with 54 litre cleaning fluid capacity. Fluid re-circulated through replaceable filter element and directed onto
workpiece through flexible metal delivery nozzle. The tank lid is fitted with fusible link hinge that will automatically snap the lid shut in the event
of a fire. NOTE: This tank is considered safe for use in hazardous environments due to the absence of electricity.
Min. Working Capacity ....................... 48l
Max. Working Capacity .......................55l
Max. Tank Capacity ......................... 91l
Pump Output ............................205l/h
Weight ..................................32kg
Original Language Version
SM22/C Issue: 2 - 17/03/10
Page view 0
1 2 3

Summary of Contents

Page 1 - MODEL No:

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly mai

Page 2 - 4. AIR SUPPLY

 WARNING! Read and apply Section 1 safety instructions before using the cleaning tank. IMPORTANT! You must remove the transit bolt from the

Page 3 - PARTS LIST FOR:

First Issued: 130700 Version No: 1 Date Modified: 231100Fig.2 Item Part No. Description 1 SM22/C/01 BODY 2 SM22/C/02 COVER 3

Comments to this Manuals

No comments