Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained,
give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
2. INTRODUCTION & SPECIFICATIONS
WARNING! Turn off, or disconnect from, air supply before servicing or performing any maintenance and when unit is not in use.
Failure to comply with this instruction may damage the unit and will invalidate your warranty.
WARNING! Wear approved ear, eye, hand and respiratory protection when operating the blaster. A full range of personal safety equipment
is available from your Sealey dealer.
 Maintain correct balance and ensure firm footing.
Spillages of abrasive material, which may be slippery, must be cleaned up immediately to avoid injury.
Locate blaster in a suitable, well ventilated, work area. Keep area clean and tidy and free from unrelated materials, and ensure that there
is adequate lighting.
Maintain the blaster in good condition (use an authorised service agent).
Replace or repair damaged parts. Use recommended parts only. Non-authorised parts may be dangerous and will invalidate the warranty.
Keep the unit clean for best and safest performance.
Remove ill fitting clothing. Remove ties, watches, rings, other loose jewellery and contain long hair.
Always keep the blast nozzle directed at the workpiece.
If a failure or malfunction occurs immediately disconnect from air supply.
Keep all other persons away from the working area. Contact with high pressure blast or inhaling the dust generated is dangerous.
DO NOT use the blaster for any purpose other than that for which it is designed.
DO NOT operate the blaster if any parts are missing or damaged as this may cause failure and/or personal injury.
DO NOT use any abrasive which contains free silica. We recommend Sealey Shot Blasting Grit, item B/25KG.
DO NOT attempt to clear a blocked nozzle while the unit is pressurised.
DO NOT allow untrained persons to operate the blaster.
DO NOT get the blaster wet or use in damp or wet locations or areas where there is condensation.
DO NOT leave the blaster operating unattended.
DO NOT operate the blaster when you are tired, under the influence of alcohol, drugs or intoxicating medication.
DO NOT stand or sit on the blaster.
DO NOT direct air from the air hose at yourself or others.
DO NOT operate system with air supply exceeding 120psi (8.2 bar).
INSTRUCTIONS FOR:
WORKSHOP SHOT BLASTERS
Model Nos:
SB994, SB995
Compact and portable shot blasting kit. Large capacity hopper with
handle and heavy-duty rubber wheels for easy manoeuvrability. Supplied
with 3.0mtr grit hose, fitted with a heavy-duty shot blasting gun and four
ceramic nozzles.
Model: SB994 SB995
Maximum Fill Weight: 22.6kg 40kg
Working Pressure: 60 ~ 120psi
Air Requirements: 10 ~ 16cfm
Air Inlet Size: 1/4” BSP
Ceramic Nozzle Sizes: 4, 5, 6 & 7mm
Overall Size (L x W x H): 370 x 330 x 685mm 432 x 458 x 940mm
Nett Weight: 4.4kg 11.4kg
3. AIR SUPPLY
WARNING! Ensure the air supply does not exceed 120psi (8.2 bar) while operating the unit. Too high an air pressure will shorten the
life of the unit due to excessive wear and may cause damage and/or personal injury.
3.1 Ensure the blaster air valve (trigger) is in the ‘Off’ position before connecting to the air supply.
3.2 Keep the air hose between the compressor and the unit a reasonable length and install an air filter and water separator (fig.1).
3.3 Drain the air tank daily. Water in the air line will damage the unit.
3.4 The recommended hook-up procedure is shown in fig.1.
3.5 The minimum hose diameter should be 1/4" I.D. and
fittings must have the same inside dimensions.
3.6 Use correct hoses and fittings. DO NOT use quick
change couplings as they add weight and can cause
failure due to vibration. Add a leader hose and connect
coupling between this and supply hose.
3.7 Keep hoses away from heat, oil and sharp edges. Check
hoses for wear and ensure that all connections are
secure.
fig.1
Original Language Version
SB994, SB995 Issue: 2 - 12/10/09
Page view 0
1 2

Summary of Contents

Page 1 - SB994, SB995

Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly mai

Page 2 - 5. OPERATION

4. ASSEMBLY 5. OPERATION WARNING! Before operating the unit ensure you read, understand and apply Section 1 Safety Instructions. NOTE: Numbe

Related models: SB995

Comments to this Manuals

No comments