INSTRUCTIONS FOR:
PROFESSIONAL AIR REGULATOR, FILTER,
LUBRICATOR RANGE
MODEL No's: SA306, SA306FR, SA306L, SA306F, SA306R.
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
1. SAFETY INSTRUCTIONS
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.
USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
 WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment.
 WARNING!Disconnect the equipment from the air supply before changing accessories,servicing or performing any maintenance.
 Keep the equipment clean and maintain it in good condition (use an authorised service agent).
 Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 WARNING! Ensure that the correct air pressure is maintained and not exceeded.
 Keep air hoses away from heat, oil and sharp edges. Check hoses for wear before each use and ensure that all connections are secure.
 DO NOT direct air from the air hose at yourself, others or animals.
DO NOT operate air tools when tired or under the influence of drugs, alcohol or intoxicating medication.
 Drain the compressor air tank and the filter bowl daily. Water in the air line will damage your equipment.
 When work is complete ensure that the air supply is turned off.
2.1. Introduction
Suitable for industrial workshop air supply set-ups where high flow applications are required. State of the art design for the professional user.
Regulator assemblies feature locking control knob for pre-setting air pressure and an easy-to-read digital pressure gauge. Fitted with
manual drain facility. Both filters and lubricators are fitted with metal bowl cages for protection.
2.2. Specifications
2. INTRODUCTION & SPECIFICATIONS
Filter/Lubricator/Regulator - SA306
Max. inlet pressure ............................174psi
Max. outlet pressure ...........................145psi
Max. flow rate @ 100psi .......................63.5cfm
Lubricant ........Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports:Inlet ...................................¼”BSP
Outlet ..................................¼”BSP
WARNING! Filter and lubricator bowls are manufactured
from polycarbonate and must not be used at temperatures
over 140°F (60°C) or for pressures over 170psi (12bar).
Polycarbonate can be damaged and may fail if exposed to
certain solvents either internally or externally, such as
strong alkalies, compressor oils containing aromatic
hydrocarbons or fire retardant oils, or the fumes of any of
these. Clean with warm water only.
SA306 SA306FR
SA306F
SA306L
SA306R
Original Language Version
SA306/306F/306FR/306L/306R Issue: 1 - 30/07/12
Filter - SA306F
Max. inlet pressure ............................174psi
Max. outlet pressure ...........................145psi
Max. flow rate @ 100psi .........................74cfm
Ports:Inlet ...................................¼”BSP
Outlet ..................................¼”BSP
Filter/Regulator - SA306FR
Max. inlet pressure ............................174psi
Max. outlet pressure ...........................145psi
Max. flow rate @ 100psi .......................63.5cfm
Ports:Inlet ...................................¼”BSP
Outlet ..................................¼”BSP
Lubricator - SA306L
Max. inlet pressure ............................174psi
Max. outlet pressure ...........................145psi
Max. flow rate @ 100psi .......................77.5cfm
Lubricant ........Sealey Air Tool Oil - ATO/500 or ATO/1000
Ports:Inlet ...................................¼”BSP
Outlet ..................................¼”BSP
Regulator - SA306R
Max. inlet pressure ............................174psi
Max. outlet pressure ...........................145psi
Max. flow rate @ 100psi .........................60cfm
Ports:Inlet ...................................¼”BSP
Outlet ..................................¼”BSP
© Jack Sealey Limited 2012
Page view 0
1 2

Summary of Contents

Page 1 - LUBRICATOR RANGE

INSTRUCTIONS FOR: PROFESSIONAL AIR REGULATOR, FILTER, LUBRICATOR RANGE MODEL No's: SA306, SA306FR, SA306L, SA306F, SA306R.Thank you for purchasin

Page 2 - 01284 703534

4. OPERATION4.1. Digital Pressure Gauge4.1.1. SA306, 306FR and SA306R are fitted with a digital pressure gauge (fig.2). Press the function button

Related models: SA306FR | SA306L | SA306R | SA306 |

Comments to this Manuals

No comments