INSTRUCTIONS FOR:
TUNGSTEN/HALOGEN FLOODLIGHT WITH
WALL BRACKET & PIR SENSOR 400W/230V
MODEL No: MD520C.V2
Thank you for purchasing a Sealey product. Manufactured to a
high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE, OR PERSONAL INJURY, AND WILL INVALIDATE THE WARRANTY.
1. SAFETY INSTRUCTIONS
4. INSTALLATION INSTRUCTIONS
2. INTRODUCTION
3. SPECIFICATION
fig 1.
fig 2.
Original Language Version
MD520C.V2 Issue: 1 - 07/01/11
1.2. GENERAL SAFETY.
 WARNING! Turn off the mains power supply before changing
tubes, servicing or performing any maintenance.
Maintain the light in good condition (Repairs must only be undertaken
by a qualified electrician).
Replace or repair damaged parts. Use genuine parts only, non
authorised parts may be dangerous and will invalidate the warranty.
Ensure the light is installed correctly in accordance with these
instructions.
Only install the light on a vertical surface. DO NOT fix the light on any
horizontal surface i.e. ceiling, or overhang.
Light becomes very hot. Installation must be away from flammable or
combustible materials such as wood, cloth, paper etc.
DANGER! DO NOT direct the light into a persons eyes. This unit
has a very intensive light output, which if incorrectly used could
cause eye damage.
DO NOT install the light where it is likely to be knocked or hit.
DO NOT install in bathrooms, shower rooms, sauna or such locations.
DO NOT install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc.
DO NOT touch the light when operating, allow to cool before touching,
light operates at high temperature.
DO NOT handle halogen bulbs as the natural oil from your fingers and
hands will shorten the bulb life. Handle only with a soft cloth.
DO NOT use the light without the front glass shield. Avoid touching the
glass shield as handling may reduce its serviceable life and cause the
glass to crack.
DO NOT use the light near flammable, combustible or explosive
liquids, solids, gases or equipment.
Specifications:
Power: .....................................................................................................230Volt.
Bulb: ................................................................400Watt Tungsten/Halogen tube.
Detection Angle: ..................................................................... 120° (Fan shape).
Detection Range: ..................................................................... 12m (Adjustable).
Time Delay: .............................................6 seconds to 20 minutes (Adjustable).
Light Sensitivity: .................................................................. 30 Lux (Adjustable).
Replacement Tube: .............................................................................. ML400B.
1.1. ELECTRICAL.
 WARNING! It is the user’s responsibility to read, understand and
comply with the following:
WARNING! THIS PRODUCT MUST BE INSTALLED BY A QUALIFIED
ELECTRICIAN.
You must check all electrical equipment and appliances to ensure they
are safe before using. You must inspect power supply leads, plugs and
all electrical connections for wear and damage. You must ensure the risk
of electric shock is minimised by the installation of appropriate safety
devices. An RCCB (Residual Current Circuit Breaker) should be
incorporated in the main distribution board. You must also read and
understand the following instructions concerning electrical safety.
1.1.1. Ensure the light is connected to an appropriate electrical on/off switch.
1.1.2. Ensure the insulation on all cables and the product itself is safe before
connecting to the mains power supply.
1.1.3. Ensure that cables are always protected against short circuit and
overload.
1.1.4. Regularly inspect power supply, leads, plugs and all electrical
connections for wear and damage, especially power connections, to
ensure that none are loose.
1.1.5. Important: Ensure the voltage marked on the product is the same as
the electrical power supply to be used.
1.1.6. DO NOT pull power cable once installed.
1.1.7. DO NOT pull power plugs from sockets by the power cable.
1.1.8. DO NOT use worn or damaged leads, plugs or connections.
Immediately replace or have repaired by a qualified Electrician.
Ensure the unit is correctly earthed and wired according to the
diagram figure 1 below.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
After wiring, check there are no bare wires, that all wires have been
correctly connected and that the wire restraint is tight.
Infrared detector unit automatically switches 400Watt tungsten/halogen lamp on
when approached by vehicles or persons. Detects movement and heat and is
fitted with adjustable sensitivity and light duration controls. Supplied with wall
mounting bracket and full operating instructions. Supplied without mains cable
and suitable for outdoor mounting.
WARNING! DO NOT connect unit to the mains power supply
before installation. When ready, the lamp must only be connected
to the mains by a qualified electrician.
4.1. Fitting
Give careful consideration to the position of unit to ensure you obtain
maximum benefit from the lighting range, and that an appropriate
electrical power source can be provided.
4.1.1 DO NOT install near an exhaust outlet. i.e. Boiler flue, dryer outlet, etc
as variance in temperature will effect the sensitivity of light. The light
must be mounted on a vertical surface only i.e. on a wall etc.
DO NOT mount on a horizontal surface i.e. ceiling or an overhang,
DO NOT mount so that the face of the lamp is pointing upwards, or is
facing towards the mounting surface. An approximate appropriate
mounting height from the ground is 2.5m.
4.1.2 To protect surfaces and objects from the light’s heat, fix at following
minimum distances between light and any surface/object, (fig 2A).
500mm minimum between the top of the light and any overhead
surface, or objects, i.e. ceilings, overhangs. 200mm between sides of
light and end or side walls, surface or objects. 2 metres minimum
between the front of the light and any object to be illuminated.
Fix the light to vertical surface with appropriate fixings. Do not tilt the
light back beyond 30° (fig 2B) or forward more than 45° (fig 2C).
Page view 0
1 2 3

Summary of Contents

Page 1 - MD520C.V2

INSTRUCTIONS FOR:TUNGSTEN/HALOGEN FLOODLIGHT WITH WALL BRACKET & PIR SENSOR 400W/230V MODEL No: MD520C.V2Thank you for purchasing a Sealey product

Page 2 - 01284 703534

4.2. Sensor The sensor may be angled independently of the light. Mounted at approximately 2.5m above the ground the sensor will have approx 12m

Page 3 - OF CONFORMITY

EC DECLARATIONOF CONFORMITYWe the sole importers into the UK, hereby declare that the equipment described belowDescription and Function:.....

Related models: LED110S | LED120S | LED130S |

Comments to this Manuals

No comments