Heavy duty three phase compressors suitable for the professional
workshop. Two stage pump system coupled with a 7.5hp motor
maximises performance to keep running costs low compared to
single stage single phase models. 500ltr tank allows for longer
continuous air tool operation and less start ups so using less power,
saving on running costs. Pumps feature heavy duty full cast
cylinders, capped by alloy heads for improved heat dissipation and
long life. Heavy duty drive guards protect belt and flywheel, that is
designed to force air over the pump to aid cooling. Supplied with full
CE certification, test certificates and operating/maintenance manual.
Model: ........................................................................... SAC55075B
Motor Output (HP): .................................................................... 7.5hp
Voltage/Phase: ...................................................................... 415-3hp
Input current: ................................................................................ 16A
Speed (rpm): .............................................................................. 1280
Air Displacement (cfm/Lm): ................................................. 29.3(380)
Max Free Air Delivery (cfm/Lm): ..........................................22.6(640)
Max Pressure (psi/bar): ........................................................... 145/10
Tank Capacity (L): ........................................................................ 500
Dimensions (WxDxH) (mm): ........... ................ .....2000 x 700 x 1230
Net Weight (kg): ........................................................................255kg
SAC55075B Issue: 1 - 24/12/14
Original Language Version
© Jack Sealey Limited
2. INTRODUCTION
4. OPERATION
fig.3
3. SPECIFICATIONS
4.1. Preparation
4.1.1. Remove compressor from the packaging.
4.1.2. Confirm that the mains voltage corresponds with the voltage
shown on the compressor data plate. Fit a suitable 3 pin
industrial plug - see section 1.1.10. of the Safety Instructions.
4.1.3. Take care to transport the compressor correctly, DO NOT
overturn it or lift it with hooks or ropes.
4.1.4.Positionthecompressoronaat,horizontalsurfaceand
ensure it is securely bolted down. Site in a well ventilated
area, protected against atmospheric pollution and not in a
placesubjecttoexplosionhazard.
4.1.5. Toensuregoodventilationandefcientcooling,thecompressor’s
beltguardmustbeatleast100cmfromanywall(g.3).
4.1.6. Remove the plastic transit plug from the oil filler hole, if fitted,
(fig.4) and replace it with the dipstick. It is a push fit.
4.1.7. Before using the compressor, check the oil level in the
sight glass in fig.2. If the oil is not up to the max. mark, it should
be topped up with synthetic oil (see section 5.7. for
recommended oils). We DO NOT recommend using mineral oil
in these compressors. DO NOT overfill.
7 DO NOT operate the compressor without an air filter.
7 DO NOT allow anyone to operate the compressor unless
they have received full instructions.
WARNING! The air tank is a pressure vessel and the
following safety measures apply:
7 No welding operations are to be carried out on any
pressurised parts of the vessel.
7 DO NOT tamper with the safety valve, DO NOT modify or alter
the tank in any way and DO NOT strap anything to the tank.
7 DO NOT subject the tank to impact, vibration or to heat and
DO NOT allow contact with abrasives or corrosives.
3 Drain condensation from tank and inspect inside walls for
corrosion as per the maintenance schedule and have a
detailed tank inspection carried out annually. The tank shell
must not fall below the certified thickness at any point.
WARNING! If an electrical fuse blows, ensure it is replaced
with an identical fuse type and rating.
3 When not in use for a prolonged period, and if possible, store
the compressor carefully in a safe, dry, childproof location.
4. CONTENTS
1. Direct compressed air outlet.
2. Tank.
3. Pressure gauge.
4. Pressure switch.
5. Electric motor.
6. Belt guard
7. Compressor unit.
8. Non return valve.
9. Safety valve.
10. Condensate drain.
fig.2
fig.4
GENERAL SAFETY CONTINUED:
3 Keep tools and other items away from the compressor when
it is in use, and keep area clean and clear of unnecessary
items.
3 Ensure the air hose is not tangled, twisted or pinched.
3 Keep children and unauthorised persons away from the
working area.
7 DO NOT dis-assemble compressor for any reason. The unit
must be checked by qualified personnel only.
7 DO NOT use the compressor outdoors, or in damp, or wet,
locations
7 DO NOT operate within the vicinity of flammable liquids,
gases or solids.
7 DO NOT touch compressor cylinder, cylinder head or pipe
from head to tank as these may be hot.
7 DO NOT use this product to perform a task for which it has
not been designed.
7 DO NOT deface the certification plate attached to the
compressor tank.
7 DO NOT cover the compressor or restrict air flow around the
unit whilst operating.
q DANGER! DO NOT direct the output jet of air towards people
or animals.