Sealey WPP1100 User Manual

Browse online or download User Manual for Pumps Sealey WPP1100. Sealey WPP1100 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
1.2. GENERAL SAFETY
 WARNING! This pump must be used in accordance with Health & Safety, government, local authority and water authority rules and
regulations including appropriate procedures for the protection of persons, animals, equipment and property.
Familiarise yourself with application, limitations and potential hazards peculiar to the pump.
 WARNING!Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
 WARNING!DO NOT have contact with the water whilst the submerged pump is connected to the mains supply.
Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
 Switch off the power on all devices that are in contact with the water before carrying out any cleaning or maintenance work on the device.
DO NOT use the pump for any purpose other than for which it is designed.
DO NOT operate the pump out of water. The pump pick-up area must be completely submerged during operation.
DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
DO NOT carry the pump by its electrical cable, or outlet pipe.
DO NOT use the device in water additionally chlorinated or in acidic or alkaline solutions.
DO NOT use in salt water.
DO NOT let the pump run dry. This can cause irreparable damage.
1.1. ELECTRICAL SAFETY
WARNING! It is the owner’s responsibility to read, understand and comply with the following:
You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs and all electrical
connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of appropriate safety devices. An RCCB (Residual
Current Circuit Breaker) should be incorporated in the main distribution board. We also recommend that an RCD
(Residual Current Device) is used with all electrical products. It is particularly important to use an RCD together with portable products that are plugged into an
electrical supply not protected by an RCCB. If in doubt consult a qualified electrician. You may obtain a Residual Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. The Electricity At Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified electrician, using a
Portable Appliance Tester (PAT), at least once a year.
1.1.2. The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of the appliance and the safety of the
appliance operator. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure the insulation on all cables and the product itself is safe before connecting to the mains power supply. The pump and cable are designed for
submerging in water and as such must not be tampered with (if in doubt, contact a qualified electrician).
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. Regularly inspect power supply leads, plugs and all electrical connections for wear and damage, especially
power connections, to ensure that none is loose.
1.1.6. Important: Ensure the voltage marked on the product is the same as the electrical power supply to be used,
and check that plugs are fitted with the correct capacity fuse. A 13 amp plug may require a fuse smaller than
13 amps for certain products, see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by its power supply lead.
1.1.8. DO NOT pull power plugs from sockets by the power cable.
1.1.9. DO NOT use worn or damaged leads, plugs or connections. Immediately replace or have repaired by a
qualified electrician.
A U.K. 3 pin plug with ASTA/BS approval is fitted. In case of damage, cut off and fit a new plug
according to the following instructions (discard old plug safely).
(UK only - see diagram at right). Ensure the unit is correctly earthed via a three-pin plug.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
1.1.10. The electrical cable is designed for use in water and must not be substituted. If damaged contact a qualified electrician.
1.1.11. Extension cable use. Only use a cable designed for use with water equipment. Contact your dealer or a qualified electrician for advice.
Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet hands.
INSTRUCTIONS FOR:
SUBMERSIBLE POND PUMP
MODEL No: WPP1100
1. SAFETY
2. INTRODUCTION & SPECIFICATION
A pond pump suitable for creating garden water fountain features. It also provides the
important functions of filtration and water circulation which are necessary to maintain healthy
plant and fish life. WPP1100 comes with two fountain heads Cascade and Water Bell.
The pumps compact design makes it very powerful yet at the same time energy efficient.
A magnetic impeller is driven by a leak proof synchronous motor.
Technical Data.
Model No: WPP1100
Power Consumption: 230V 20W
Max. Head: 1.1mtr
Max. Flow Rate: 1100ltr/hr
Max. Submersion Depth: 3mtr
Power Cable: 10mtr
Max. Temp. of the Pumped Fluid: 35°C
Protection Type: IP68
Water Bell
Cascade fountain
Outlet pipe
Pump
Rubber feet
Original Language Version
WPP1100 Issue:5 (S) - 17/09/14
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE
PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
© Jack Sealey Limited
SUGGESTED FUSE
RATING: 5A
This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning use of the appliance in a safe way and
understand the hazards involved. Children shall not play with the appliance. Cleaning and
user maintenance shall not be made by children without supervision
Page view 0
1 2

Summary of Contents

Page 1 - SUBMERSIBLE POND PUMP

1.2. GENERAL SAFETY WARNING! This pump must be used in accordance with Health & Safety, government, local authority and water authority rules

Page 2 - 4. MAINTENANCE

Environmental ProtectionRecycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken

Comments to this Manuals

No comments